Problems in the debugging of Refrigerated high-speed centrifuge software

2018/5/10 15:59:27      click :

Refrigerated high-speed centrifuge is a kind of centrifuge that is more common in the modern centrifugal market. It is widely used in clinical medicine, biochemistry, genetic engineering, immunology and other fields, and is used by modern hospitals, research institutes, and institutions of higher learning. One of the necessary instruments for centrifugal separation.
Through this article, you will learn about the knowledge of Refrigerated high-speed centrifuge software debugging and operation, hope to read the article after the use of your centrifuge can help.
First, the Refrigerated high-speed centrifuge software running process
In the debugging of the prototype, we have determined the control subroutines of seven different rotor models, which are suitable for the rotor of several thousand to thirty thousand revolutions. In actual operation, the user needs to use the keyboard to input their own needs. The rotor model can be.
Second, the results of Refrigerated high-speed centrifuge software operation
Throughout the entire operation process, the centrifuge is in a state of control failure and system mechanical failure. It is timely to detect and alarm, and promptly close all control objects to minimize the loss of the centrifuge, and at the same time, if it is running If any abnormality is found in the system, for example, the key is damaged, the display is abnormal, etc., the operator should be promptly alerted and the related records should be made.
Third, solve problems in Refrigerated high-speed centrifuge debugging
1. During the operation of the Refrigerated high-speed centrifuge, due to the limitations of the centrifugal environment, it is susceptible to all kinds of interference, which easily causes the phenomenon of “runaway” in the Refrigerated high-speed centrifuge program. For this reason:
1) The user can take relevant software anti-jamming measures to avoid this problem;
2) In addition to white reset measures on the product hardware, it is also necessary to strengthen the shielding and isolation measures;
3) Use separate power supply (and phase separation of interference source) or install UPS power supply for Refrigerated high-speed centrifuges;
4) The addition of the IRC absorption circuit to the relay coil can also avoid this problem.
2. In the course of operation, it is also prone to the unstable state of the sampling signal, which affects the reliability of the Refrigerated high-speed centrifuge. In such a situation, we suggest that the hardware filtering circuit can be used in the pre-stage to solve the problem.
More information about Refrigerated high-speed centrifuge, please call!